Product Overview: At a Glance

The Hitachi KPI Passive Total Heat Exchanger delivers efficient energy recovery ventilation (ERV) to improve indoor air quality and reduce HVAC load. With a cross-flow celluloid exchanger and a broad flow rate capacity range - from 250 m³/h up to 2,000 m³/h, it’s an ideal solution for buildings aiming to balance fresh air intake with energy efficiency.

Key Features & Benefits

  • High energy recovery - reaches an impressive total energy exchange efficiency up to ~83%, Transfers both heat and moisture between air streams for cost savings
  • Wide airflow options - available across variants from KPI-252E4E (250 m³/h) to KPI-2002E4E (2,000 m³/h), supporting mixed-use commercial and residential spaces
  • Multiple operating modes - supports free ventilation, automatic ventilation, and heat recovery to maximise efficiency and air quality control
  • Ultra-quiet operation - uses ErP Lot 11-compliant fan motors with noise levels as low as 24 dB(A) on select models
  • Compact design - relatively small footprint (e.g. KPI-252E4E: 900 × 270 × 750 mm) fits ducted systems with installation flexibility
  • Optional enhanced filtration & control - supports CO₂ sensor integration and high-efficiency F7 filters for improved air purification

Typical Applications & Use Cases

Ideal for offices, apartments, schools, and energy-conscious commercial environments, the KPI Passive Total Heat Exchanger provides continuous fresh air with heat and moisture recovery; boosting comfort, maintaining indoor air quality, and reducing HVAC strain.

Technical Overview

The KPI series includes models like KPI-252E4E, KPI-502E4E, KPI-802E4E, KPI-1002E4E, KPI-1502E4E, and KPI-2002E4E, each offering a specific airflow range, efficiency, and casing size. All are based on cross-flow celluloid heat exchanger technology and operate on standard single-phase 230 V power supply. With energy recovery up to 83% and fitted with a low-consumption electronically commutated motor, this unit is well-placed to lower running costs for your installation. For full specifications, including dimensions, efficiency rating, noise levels, and static pressure - please refer to any of the documentation on this page.

Please contact us for delivery information & quotes. Thank you.

Items on this page may also be known under the following references:

  • KPI
  • KPI Energy & Heat Recovery
  • Energy Recovery Exchangers

Additional Downloads:

No downloads available.

  • Premium Aftercare
  • Flexible Returns
  • Fast Shipping
Enquire About This Product View full details
Your cart
Variant Variant total Quantity Price Variant total
Ventilation system with two ducts on a white background
250 m³/h Airflow (KPI-252E4E)KPI-252E4E
250 m³/h Airflow (KPI-252E4E)KPI-252E4E
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Ventilation system with two ducts on a white background
500 m³/h Airflow (KPI-502E4E)KPI-502E4E
500 m³/h Airflow (KPI-502E4E)KPI-502E4E
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Ventilation system with two ducts on a white background
800 m³/h Airflow (KPI-802E4E)KPI-802E4E
800 m³/h Airflow (KPI-802E4E)KPI-802E4E
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Ventilation system with two ducts on a white background
1000 m³/h Airflow (KPI-1002E4E)KPI-1002E4E
1000 m³/h Airflow (KPI-1002E4E)KPI-1002E4E
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Ventilation system with two ducts on a white background
1500 m³/h Airflow (KPI-1502E4E)KPI-1502E4E
1500 m³/h Airflow (KPI-1502E4E)KPI-1502E4E
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Ventilation system with two ducts on a white background
2000 m³/h Airflow (KPI-2002E4E)KPI-2002E4E
2000 m³/h Airflow (KPI-2002E4E)KPI-2002E4E
Regular price
£0.00
Sale price
£0.00/ea
£0.00
Regular price
£0.00
Sale price
£0.00/ea
£0.00

View cart
0

Total items

£0.00

Product subtotal

Taxes included. Discounts and shipping calculated at checkout.
View cart

Interested in this product?

We can provide any item listed on our website for you, please fill out the form below with your requirements and a member of our team will get back to you shortly.

Enquire about this product


Hitachi KPI Passive Total Heat Exchanger with Celluloid Exchanger FAQs

What is MVHR?
MVHR (Mechanical Ventilation with Heat Recovery) is a system that provides fresh, filtered air while recovering heat from the outgoing stale air.
How does MVHR improve energy efficiency?
By recycling heat from extracted air, MVHR reduces the energy needed to warm incoming air - cutting heating bills and supporting sustainable building design.
Is MVHR suitable for UK homes and businesses?
Yes. MVHR is increasingly used in new-build homes, offices, and schools across the UK, particularly where airtight construction demands controlled ventilation.

We’re Here To Help With All Hitachi MVHR Systems

Need any help with our range of Hitachi Passive KPI products? Our specialists provide comprehensive support with Hitachi MVHR systems (Mechanical Ventilation with Heat Recovery) for residential and commercial projects. We can assist with product selection, system design, and integration with wider HVAC equipment in order to maximise energy efficiency and indoor air quality. Whether you’re planning a new build or retrofitting, our knowledge of Hitachi MVHR technology ensures reliable results. Contact us today for expert guidance on all Hitachi MVHR solutions.